ORIGINAL ARTICLE
Int J Env Health Eng 2015,  4:11

Performance evaluation of tertiary treatment through ultrafiltration: Case study in Isfahan-industrial wastewater treatment plant


1 Department of Environmental Health, School of Public Health, Shahrekord University of Medical Sciences, Rahmatie, Shahrekord, Iran
2 Environment Research Center, Research Institute for Primordial Prevention of Non-Communicable Disease, Isfahan University of Medical Sciences (IUMS); Department of Environmental Health Engineering, School of Health, IUMS, Isfahan, Iran
3 Department of Environment, Isfahan Industrial Estates Co., Isfahan, Iran
4 Department of Environment, Isfahan Industrial Estates Co.; Environment Research Center, Isfahan University of Medical Sciences (IUMS); Department of Environmental Health Engineering, Student Research Center , School of Health, IUMS, Isfahan, Iran

Date of Web Publication27-May-2015

Correspondence Address:
Mahnaz Heidari
Department of Environmental Health, School of Public Health, Shahrekord University of Medical Sciences, Rahmatie, Shahrekord
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2277-9183.157688

Rights and Permissions
  Abstract 

Aims: The aim of this study was the performance evaluation of ultrafiltration (UF) membrane process as an advanced treatment to secondary effluent quality improvement in Isfahan - Morchekhort Industrial Estate wastewater treatment plant.
Materials and Methods: Membrane system used in this study included a flat sheet UF module of polysulfone with 0.1 μm pore size. The coagulation, flocculation and sedimentation (Coag, Floc, Sed) and rapid sand filtration in conjunction with granular activated carbon (GAC) filtration was used as pretreatment of secondary effluent. All test methods was obtained of standard method for the examination of water and wastewater.
Results: The membrane system could decrease turbidity, chemical oxygen demand (COD), total suspended solids (TSS), total hardness (TH), total coliform (TC), fecal coliform (FC), total nitrogen (TN) and Cl , 24.5, 19, 48, 10.5, 94.5, 85.1, 15.4 and 1.01%, respectively.
Conclusion: UF was able to improve chemical parameters of secondary effluent and meet national environmental standards. However, achievement to optimum operation of this system requires adequate pretreatments such as adding filter aid, sand filtration and GAC. The most part of suspended particles expressed by turbidity was removed within UF membrane, whereas only a little of organic substance expressed by COD or color and salt expressed by conductivity could be removed.

Keywords: Coagulation and flocculation, granular activated carbon, industrial estate wastewater, sand filtration, ultrafiltration


How to cite this article:
Khodabakhshi A, Heidari M, Amin MM, Momeni SA, Ebrahimi H. Performance evaluation of tertiary treatment through ultrafiltration: Case study in Isfahan-industrial wastewater treatment plant. Int J Env Health Eng 2015;4:11

How to cite this URL:
Khodabakhshi A, Heidari M, Amin MM, Momeni SA, Ebrahimi H. Performance evaluation of tertiary treatment through ultrafiltration: Case study in Isfahan-industrial wastewater treatment plant. Int J Env Health Eng [serial online] 2015 [cited 2021 Sep 20];4:11. Available from: https://www.ijehe.org/text.asp?2015/4/1/11/157688


  Introduction Top


Water is becoming an increasingly scarce resource in many populated areas and a major factor for industrial estates at all over the world. [1],[2] Many industrial processes rely on the availability and reliability of their water supplies and usually compared with geographical and seasonal fluctuations associated with the use of water for agriculture and irrigation, fairly use a constant amount of water during a year. Therefore, such industries provide a special opportunity for use of reclaimed water. After 1990 industry becomes a necessity by observation strict environmental targets specifically for wastewater discharge. [3]

In these conditions UF, reverse osmosis (RO) and nano filtration (NF) have been widely used for the full-scale treatment and reuse. Karakulski et al., [4] Koítuniewicz and Field, [5] Marchese et al., [6] Salahi and Mohammadi, [7] Fateme et al., [8] Mohammadi and Esmaeelifar [9],[10] examined the feasibility of using polymer and ceramic membrane for municipal and industrial wastewater treatment. These processes have more benefits compared with conventional membrane processes. UF is a membrane separation process with low pressure used for selected compounds separation according to their size. [8]

UF membranes are capable to particular maintain with molecular weights 300-500000 Dalton and pore sizes 10-1000 Angstrom. This method usually used for separate macromolecules such as proteins from solvents with low molecular weight. [11] These membranes can't remove sugars and salts. [12]

UF membrane pore size and surface hydrophobicity is effective on the flux decline, fouling reversibility and fates of proteins. [13]

In evaluating the effectiveness of micro filtration (MF)/UF compared to conventional pretreatment, it is important to consider the cleaning level, back washing and maintenance required by the MF/UF system. [14]

MF and UF known as solid/liquid separation membranes that were able to remove suspended and colloidal particles including microorganisms. [15] These could remove high levels of bacteria, oocytes and protozoa cysts. [16]

MF and UF technologies both in effluent filtration as well as in membrane bioreactors are also suitable as pretreatment to NF or RO. Such physical barrier-processes are attractive in wastewater treatment because any technology employed must be able to produce reused water of uniform quality, regardless of the normally wide variation in the concentration or physicochemical properties of wastewater influent [17],[18] and the absence of chemicals addition is of economic and ecological benefit. [19]

In an article in 2008, Goren et al., in southern occupied Palestine, with another review on coagulation and adsorption by powdered activated carbon and UF as tertiary treatment of sewage effluent, found a result of less than three for total organic carbon (TOC) that could be used for unrestricted irrigation. TOC reduction result in minimizing the membrane fouling. [20] Coagulation, sedimentation and filtration stages removed a large amount of suspended solids, colloidal particles and organic matter. [21]

Marcucci and Tognotti demonstrated ozonation with activated carbon filter is more effective in reducing COD while using UF and it is more effective in removing bacteria. However, yellowish color effluent removed by ozonation could not be removed by UF. [2]

Zheng et al., in 2009 worked on the effect of slow sand filter on treatment of municipal wastewater before treatment with UF. According to their observations, direct filtration of secondary effluent applied for UF result in rapid effects fouling, because of a lot of fouling in the secondary effluent. The foulants compounds in wastewater could be removed using slow sand filter, significantly improved UF performance. [22]

The purpose of this study was to investigate of the UF membrane process influence as an advanced treatment system to obtain high quality effluent for sustainable reclamation and reuse of industrial wastewater.


  Materials and methods Top


Wastewater source and properties

The wastewater used in this work was collected from an industrial wastewater treatment plant located in the Mourchekhort Industrial Estate, on 50 km-North West of Isfahan, center of Iran. The capacity of the available treatment plant was about 2000 m 3 /d. The wastewater treatment process in this treatment plant was an anaerobic contact reactor followed by an aerobic sequencing batch reactor.

The influent westwater quality was extremely variable and its main characteristics are given in [Table 1].
Table 1: The properties of coagulation, SF, AC and water reuse quality treated by UF membrane

Click here to view


Membrane module and properties

Direct injection of wastewater into the membrane filters is not recommended. In this study in order to improve the effluent quality, we used coagulation, flocculation, sedimentation, sand filtration and activated carbon as pertreatment.

The UF module was purchased of Woongjin Chemical Co., Ltd. (South Korea) and other process equipment ' s were provided by Mirab Co. (Iran). The characteristics of UF module are summarized in [Table 2], [Table 3] and [Table 4].
Table 2: Basic characteristics of UF membrane

Click here to view
Table 3: Characteristics SF and AC used in the study

Click here to view
Table 4: Characteristics used in SF and AC media

Click here to view


Experiments

The influent wastewater was obtained of treatment plant effluent storage tank and filtrated via 5 μm filter, before pumping to the UF. Poly aluminum chloride (PACl) solution considered as a suitable coagulant. The jar test was performed to determine the optimum PACl dosage. All of the coagulation, flocculation and sedimentation processes were performed in a single package reactor. Then, effluent wastewater passed via a sand filter, caused to carbon activation and finally arrived in the UF membrane. In this study, all analyses done base of the standard method for the examination of water and waste water [Table 5]. [23]
Table 5: Physical, chemical, and microbial experiments method

Click here to view



  Results Top


The effluent quality of the coagulation system, sand filter, activated carbon and UF are shown in [Table 1].

[Table 6] shows mean ± standard deviation concentration of heavy metals included Pb, Cd, Cr, Ni and Zn. The comparisons of means percent removal of chemical and microbial parameters are present in [Figure 1] and [Figure 2]. [Figure 3] shows the efficiency of removal variable at the whole study. Change of pressure during of 1 h operation shown in [Figure 4]. The flux, temperature and pressure changes during operation also are present in [Figure 5], [Figure 6], [Figure 7].
Figure 1: Average percent removal total coliform, fecal coliform, chemical oxygen demand, and total nitrogen in treatment system

Click here to view
Figure 2: Average percent removal total suspended solids, Turbidity, and total hardness in treatment system

Click here to view
Figure 3: Efficiency of removal variable in the whole system

Click here to view
Figure 4: Change of pressure during of 1 h operation

Click here to view
Figure 5: Flux and temperature changes during operation

Click here to view
Figure 6: Pressure and temperature changes during operation

Click here to view
Figure 7: Flux and recovery changes during operation

Click here to view
Table 6: Concentration of heavy metals

Click here to view



  Discussion Top


The obtained results showed that the reduction of turbidity, COD, TSS, TH, TN, EC, total dissolved solids (TDS), fecal coliform (FC), total coliform (TC), Pb, Ni, Cr, Cd and Zn at a rate of 94, 84, 88.96, 22.61, 47.77, 1.35, 1.15, 99.73, 99.9, 50.72, 25.12, 39, 59.83 and 66.18%, respectively [Figure 3].

In this study, the coagulation showed removal efficiency of 65-80% for turbidity, TC, FC and COD and approximately 25-50% reduction in TSS and TN parameters.

The final effluent quality of UF processes highly dependent on influent wastewater properties, permeated water might be suitable for unrestricted irrigation purpose, as it is high in nutrients (N and P practically insensitive to filtration), low micro pollutant and micro organics content and exhibits favorable inorganic ratios [Table 1]. [19]

In this study, sand filtration removed suspended solid with 50 micron diameter. Contaminants were adsorbed onto the activated carbon particles, which were then separated from water by UF.

Coagulation and flocculation had a slight increase in the chloride ion, which could be because of the using PACl as a coagulant. Furthermore, due to PACl had a low pH (3.5), coagulation system output pH had been declined.

In this experiment, the elimination mean of microbial parameters - total and FC was 94.5% and 85%, respectively. Bourgeous et al., reported coliform bacteria in the effluent of UF. They used to be from membrane with size 0.01 microns that expected removed all coliform (coliform measures approximately are 0.1 microns). It was attributed to several factors such as:

  1. The membrane surface damage,
  2. precipitation of iron salts at high pH thereby protecting the bacteria even at high concentrations of disinfectants during backwashing,
  3. lowering the quality of the membrane due to the effect of bacterial enzymes or other substances and
  4. poor packing and membrane insulation units during production. [24]


Consequently, although UF can reduce great extent of the effluent coliform bacteria, but it is better to use a compilation with other disinfection methods. [24]

Long-term experiments have indicated that in vitro conditions, especially at the first 30 min, intensity of fouling is high and subsequently reduced and appears a kind of balance in the final hours, flux is almost constant. These results are similar to observations obtained by Hadian and Fateme et al. [Figure 4]. [8],[25]

During the study, the reduction of inorganic matter and microbial contents of effluent by membrane were decreased which could indicate membrane fouling. Minimum operating point in [Figure 5], [Figure 6] and [Figure 7] (episodes flux and pressure), is due to fouling of the membrane. [Figure 2], shows the flux and pressure were increased after cleaning in place (CIP) and replacement cartridge filters. The temperature rise was impressive by the addition of flux. Increase of flux after chemical cleaning had shown irreversible fouling. CIP is a manually initiated semi-automatic procedure used to wash membranes in situ.

Pearson correlation showed that an inverse relationship between flux and membrane recovery [Table 7].
Table 7: Correlation between fl ux and recovery in UF membrane

Click here to view


During the study, the inlet water temperature of the membrane was raised (change from cool season to warm season). Water permeation through the membrane increased with water temperature raised. Because viscosity of the solution is reduced and higher diffusion rate of water through the membrane is obtained. [26]

UF membrane most often use as pretreatment for RO or NF, UF pretreatment can remove a small amount of larger organic matter and colloid materials. [27]


  Conclusions Top


In industrial wastewater treatment it considered to be necessary an appropriate pre-treatment and effective cleansing system. Nonetheless, if the coagulation caused by partial removal of colloidal material is larger than the pore size UF, no effect on the removal efficiency can be seen and if the removal of colloidal material is smaller than the pore size UF result in improvement to elimination of contaminants and better filter functions.

Although large UF was able to reduce coliform bacteria in the effluent, but it had better performance with a combination of methods to be used for disinfection.

Inlet water temperature was effective on the production rate and the membrane fouling so that caused reduction in production and shortage the time to membrane fouling.

In consequent membrane must be replaced more frequently, but taken care of the membrane properly for example, backwashing system with clean water after each day's work, lifetime membrane and the each CIP time interval increases. Recommended due to the high fouling characteristics of the water, special provision was made for periodic high - velocity flushing of membranes, periodic biocide dosing and physical turbulence cleaning by means of air/water combination.


  Acknowledgments Top


Funding of this research supported by a grant from Shahrekord University of Medical Sciences and Isfahan - Iran Industrial Estate Company.

 
  References Top

1.
Tang C, Chen V. Nanofiltration of textile wastewater for water reuse. Desalination 2002;143:11-20.  Back to cited text no. 1
    
2.
Marcucci M, Tognotti L. Reuse of wastewater for industrial needs: The Pontedera case. Resour Conserv Recycling 2002;34:249-59.  Back to cited text no. 2
    
3.
Benetti AD. Water reuse: Issues, technologies, and applications. Engenharia Sanitaria e Ambiental 2008;3:247-8.  Back to cited text no. 3
    
4.
Karakulski K, Kozlowski A, Morawski A. Purification of oily wastewater by ultrafiltration. Sep Technol 1995;5:197-205.  Back to cited text no. 4
    
5.
Kol´tuniewicz AB, Field RW. Process factors during removal of oil-in-water emulsions with cross-flow microfiltration. Desalination 1996;105:79-89.  Back to cited text no. 5
    
6.
Marchese J, Ochoa N. A, Pagliero C, Almandoz C. Pilot-scale ultrafiltration of an emulsified oil wastewater. Environ Sci Technol 2000;34:2990-6.  Back to cited text no. 6
    
7.
Salahi A, Mohammadi T. Experimental investigation of oily wastewater treatment using combined membrane systems. Water Sci Technol 2010;62:245-55.  Back to cited text no. 7
    
8.
Fateme R, Salahi A, Mohammadi T, Gheshlaghi A. The application of membrane filtration process in petroleum refining wastewater treatment unit. Petroleum Res 2010;63:57-71.  Back to cited text no. 8
    
9.
Abbasi M, Mirfendereski M, Nikbakht M, Golshenas M, Mohammadi T. Performance study of mullite and mullite-alumina ceramic MF membranes for oily wastewaters treatment. Desalination 2010;259:169-78.  Back to cited text no. 9
    
10.
Mohammadi T, Esmaeelifar A. Wastewater treatment of a vegetable oil factory by a hybrid ultrafiltration-activated carbon process. J Memb Sci 2005;254:129-37.  Back to cited text no. 10
    
11.
Asgari N. A study on membrane processes. MA Thesis. Association of Chemical Engineering, Sahand University of Technology 2008;1-19.  Back to cited text no. 11
    
12.
Tchobanoglous G, Burton FL. Wastewater engineering. Management 2003;7:1-4.  Back to cited text no. 12
    
13.
Qu F, HL, Zhou J, Nan J, Shao S, Zhang J, Li G. Ultrafiltration membrane fouling caused by extracellular organic matter (EOM) from Microcystis aeruginosa: Effects of membrane pore size and surface hydrophobicity. Memb Sci 2014;449:58-66.  Back to cited text no. 13
    
14.
Durham B, Bourbigot MM, Pankratz T. Membranes as pretreatment to desalination in wastewater reuse. Memb Technol 2002;2002:8-12.  Back to cited text no. 14
    
15.
Madwar K, Tarazi H. Desalination techniques for industrial wastewater reuse. Desalination 2003;152:325-32.  Back to cited text no. 15
    
16.
Ordóñez R, Hermosilla D, San Pío I, Blanco Á. Evaluation of MF and UF as pretreatments prior to RO applied to reclaim municipal wastewater for freshwater substitution in a paper mill: A practical experience. Chem Eng J 2011;166:88-98.  Back to cited text no. 16
    
17.
Adin A, Asano T. The role of physical-chemical treatment in wastewater reclamation and reuse. Water Sci Technol 1998;37:79-90.  Back to cited text no. 17
    
18.
Alonso E, Santos A, Solis GJ, Riesco P. On the feasibility of urban wastewater tertiary treatment by membranes: a comparative assessment. Desalination 2001;141:39-51.  Back to cited text no. 18
    
19.
Wintgens T, Melin T, Schäfer A, Khan S, Muston M, Bixio D, et al. The role of membrane processes in municipal wastewater reclamation and reuse. Desalination 2005;178:1-11.  Back to cited text no. 19
    
20.
Goren U, Aharoni A, Kummel M, Messalem R, Mukmenev I, Brenner A, et al. Role of membrane pore size in tertiary flocculation/adsorption/ultrafiltration treatment of municipal wastewater. Sep Purif Technol 2008;61:193-203.  Back to cited text no. 20
    
21.
Rybicki S, Kurbiel J. Development of design criteria for the chemical precipitation process applied in cracow wastewater reclamation system. Water Sci Technol 1991;24:175-83.  Back to cited text no. 21
    
22.
Zheng X, Mehrez R, Jekel M, Ernst M. Effect of slow sand filtration of treated wastewater as pre-treatment to UF. Desalination 2009;249:591-5.  Back to cited text no. 22
    
23.
Andrew D. Standard Methods for the Examination of Water and Wastewater. American Public Health Association (APHA): Washington, DC, USA; 2005.  Back to cited text no. 23
    
24.
Bourgeous KN, Darby JL, Tchobanoglous G. Ultrafiltration of wastewater: Effects of particles, mode of operation, and backwash effectiveness. Water Res 2001;35:77-90.  Back to cited text no. 24
    
25.
Hadian R. Performance evaluation of tertiary treatment via ultrafiltration (UF) in secondary effluent treatment of Isfahan North wastewater treatment plant in pilot scale. M.A Thesis. Isfahan University of Medical Sciences; 2010.  Back to cited text no. 25
    
26.
Al-Mutaz IS, Al-Ghunaimi MA. Performance of reverse osmosis units at high temperatures. The IDA World Congress on Desalination and Water Reuse, Bahrain: IDA; October 26-31, 2001.  Back to cited text no. 26
    
27.
Juang LC, Tseng DH, Lin HY. Membrane processes for water reuse from the effluent of industrial park wastewater treatment plant: A study on flux and fouling of membrane. Desalination 2007;202:302-9.  Back to cited text no. 27
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5], [Table 6], [Table 7]



 

Top
Previous article  Next article
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Materials and me...
Results
Discussion
Conclusions
Acknowledgments
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed2947    
    Printed119    
    Emailed0    
    PDF Downloaded375    
    Comments [Add]    

Recommend this journal