ORIGINAL ARTICLE
Int J Env Health Eng 2013,  2:11

Investigation of chlorine decay of water resource in khanbebein city, Golestan, Iran


1 Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
2 Domestic Water and Wastewater Corporation of Golestan Province, Gorgan, Iran
3 Department of Environmental Health Engineering, Faculty of Health, Ilam University of Medical Sciences, Banganjab Complex, Ilam, Iran
4 Environmental Health Research Center, Golestan University of Medical Sciences, Gorgan, Iran

Date of Web Publication06-Apr-2013

Correspondence Address:
Yousuf Dadban Shahamat
Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran
Iran
Login to access the Email id

Source of Support: Golestan Water and Wastewater Company,, Conflict of Interest: None


DOI: 10.4103/2277-9183.110137

Rights and Permissions
  Abstract 

Aims: The object of the study was to identify chlorine demand factorsin water and chlorine in Kanbebein City water and eliminating of them.
Materials and Methods: Concentration of free and combined residual chlorine with the methods presented in the book "Standard Methods for Water and Wastewater Examination" were measured. Other parameters such as: Temperature, TOC, TDS, pH, EC, nitrate, ammonia, total hardness, alkalinity, iron and manganese were also examined before and after of chlorination.
Results: The Highest chlorine decay constant in the short time were in water well was 0.895 mgL -1 h -1 and the least amount of it was 0.0097 mgL -1 h -1 and the Highest chlorine decay constant in the long time were in water well was-0.092Lmg -1 h -1 and the least amount of it was-0.0017 Lmg -1 h -1 that correlated with nitrite, ammonia and iron concentration.
Conclusion: The factors that affected short-time chlorine decay constant (k 2 ) were nitrite, ammonia and iron and The factors that affected on long-time chlorine decay constant (k 2 ) were Nitrite, ammonia and iron. The material removal techniques for them were the use of natural resins, zeolite, ion exchange, membrane and aeration methods, oxidation and sedimentation, and filtration.

Keywords: Chlorination, Disinfection, Khanbebin City, water


How to cite this article:
Rahmani K, Khademi SS, Rahmani A, Godini K, Shahamat YD. Investigation of chlorine decay of water resource in khanbebein city, Golestan, Iran. Int J Env Health Eng 2013;2:11

How to cite this URL:
Rahmani K, Khademi SS, Rahmani A, Godini K, Shahamat YD. Investigation of chlorine decay of water resource in khanbebein city, Golestan, Iran. Int J Env Health Eng [serial online] 2013 [cited 2021 Jun 13];2:11. Available from: https://www.ijehe.org/text.asp?2013/2/1/11/110137


  Introduction Top


Obviously, the quality and safety of drinking water is one of the most important public health issues. Pollution of water source with pathogen microorganisms result in transferring infectious diseases and other related diseases. [1] Microbiological safety of drinking water is generally achieved by treating the water through a chemical disinfectant, usually a powerful oxidizing agent such as chlorine, chlorine dioxide or ozone. Chlorine, added to water in the form of either as hypochlorous acid/hypochlorite ion or as chlorine gas, is still the most widely applied and most cost-effective disinfectant worldwide, despite the well-known problems of disinfection by-product (DBP) formation. [2] Before treated water leaves the water treatment plant, there's chlorination unit to maintain certain chlorine residual in the distribution system. All that does is prevent microbiological regrowth. Free chlorines (HCLO - and CLO - ) are the most commonly employed disinfectants because of its remaining property in water. [3] Nevertheless, chlorine decays occurs in long distribution systems, and in areas where the chlorine concentration drops below a minimum desired level (0.2-0.8 mg/L); therefore, booster chlorination has to be installed so as to protect an enough chlorine level in the water. [4],[5]

Despite the effective use of chlorine over many decades as a disinfectant for potable water supplies, there are still regulatory failures in the quality of drinking water, which cause concern to the water utilities. [6],[7] Chlorine is a non-selective oxidant; therefore, it reacts with both organic and inorganic chemical materials in water and it also is an antimicrobial agent. Generally, in natural water bodies, the species that are most reactive with chlorine are inorganic substances in a reduced valence state such as iron (II), manganese, sulfide, bromide and ammonia. [8],[9] The presence of free chlorine residual in drinking water indicates that: A sufficient amount of chlorine is added to the water to inactivate most of the bacteria and viruses that cause diarrheal disease. The water is protected against recontamination when it is transported in the distribution system, and during storage of water in the household. Because the presence of free residual chlorine in drinking water indicates the possible absence of disease-causing organisms; therefore, it is used as one measure of the potability of drinking water. [10] Previous research has assumed first-order chlorine wall decay [11],[12],[13],[14],[15] and found to be characterized by first-order kinetics. [5] Vasconcelos et al.[5] found that a zero-order wall decay kinetic reaction was effective for characterizing the wall decay, but he also indicated that the first-order model might be better. Thus, the aim of this study was to identify and resolve problems over the use of chlorinein drinking water of Khanbbyn City.


  Materials and Methods Top


All the water samples were collected from the drinking water resources of City of Khanbebinin June 2010 [Figure 1]. The research method is in accordance with the most recent methods of determining of the chlorine demand in developed by the experts in the field. [6] The sampling process and chemical measurements of the drinking water was according to the standard book of the water and wastewater experiments.
Figure 1: The Zone of study that wells located in there

Click here to view


Four sources of the drinking water with the names (All names here are local names for water resources) Ohadi Reservoir, Klukan Reservoir, Well Number 3, and Aludarreh Reservoir as well as a resource of drinking water of Gorgan (a well in the Alimohammadi Water and Wastewater Office) were collected for comparison and investigation. Based on the experiment type, different sample volumes included 200 samples of free chlorine and 200 samples of combined chlorine, 110 samples of chemical experiments and 15 samples of TOC experiments. The hypochlorinators, installed on the concrete reservoir of the water, did the chlorination of the water. The pumps injected calcium hypochlorite powder into the reservoir, after preparation of the stock solution. The research method was in accordance with the most recent methods of determining of the chlorine developed by the experts in the field. Different concentrations of chlorine including 1, 3, 4, 5, and 7 mg/lit were solved in the water of four resources. Other parameters such as temperature, TOC, TDS, pH, EC, nitrate, ammonium nitrogen, total hardness, alkalinity, iron and manganese were measured before and after addition of chlorine in the concentration of 3 mg/lit and 30 minutes as contact time. In order to recognize the chlorine behavior in the sample, control waters in short (0 to 4 hours), and long (0 to 7 days) periods, the free and combined chlorines were measured. After the drawing, the related graphs and the calculation of the formulation of chlorine degeneration in water, optimum concentration and the causes of degeneration were determined.

The chlorine demand of each sample and the concentration of materials such as ammonia, EC, TDS, pH, Temperature, Alkalinity, Hardness, Nitrite, Nitrate, Iron and Manganese along the examination were analyzed in ANOVA statistical test and effectiveness each of them was determined.

Before addition of chlorine into water samples were added, the test of chlorine purity was carried out. To do this, first adds specific volumes of perchlorine to distilled water. Dividing the volume measured by the spectrophotometric apparatus (DR 2500) in the concentration of less than 3 mg/L into the expected concentration will give the purity degree of chlorine in different samples.


  Results Top


In order to recognize the chlorophilic factors, the chemical components of the drinking water of the city such as measuring the chlorine and chlorination of the samples were examined. The results are presented in [Table 1].
Table 1: Chemical testing of water before the chlorine Debate

Click here to view


Water and Wastewater Office carried all tests of chlorination of the samples out using the stock solution prepared using per chlorine powder provided. [Table 2] gives the degree of purity of chlorine of the samples. [Table 3] shows the amount of the water consumption of the city during the period between 2008 and 2010; the total consumption of the city was calculated in m 3 and L/s. The inlet flow of each resource was measured and is shown in [Table 4].

The graphs of the free chlorine in the water resources of the city are given below [Figure 2],[Figure 3],[Figure 4],[Figure 5],[Figure 6],[Figure 7],[Figure 8],[Figure 9],[Figure 10],[Figure 11],[Figure 12] and [Figure 13].
Figure 2: Free residual chlorine of Spring Aludareh after 24 hours

Click here to view
Figure 3: Kinetics of Short‑term decay chlorine in spring water samples from Aludareh

Click here to view
Figure 4: Kinetics of long term decay chlorine in samples from spring water Aludareh

Click here to view
Figure 5: Free residual chlorine of Kalukon well after 24 hours

Click here to view
Figure 6: Kinetics of Short‑term decay chlorine in samples from well water kalukon

Click here to view
Figure 7: Kinetics of long term decay chlorine from samples in well water Kalukon

Click here to view
Figure 8: Free residual chlorine of well No.3 after 24 hours

Click here to view
Figure 9: Kinetics of Short‑term decay chlorine in samples of well water from area No. 3

Click here to view
Figure 10: Kinetic of long term decay chlorine in samples of well water from area No.3

Click here to view
Figure 11: Free chlorine remaining of wells Ouhadi after 24 hours

Click here to view
Figure 12: Kinetics graph of short‑term decay of chlorine in samples from well water Ouhadi

Click here to view
Figure 13: Kinetics graph of long term decay of chlorine in samples from well water Ouhadi

Click here to view
Table 2: Purity percentage of chlorine in used perchlorin

Click here to view
Table 3: Water consumption of khanbebein City in various years

Click here to view
Table 4: Choice kinetic model for water resources

Click here to view


According to the experimental method, a series of chemical tests were carried out in the concentration of 3 mg/L at 30 minutes before and after adding the chlorinated solution to the water samples and paired t-test for determining the level of significance of the changes in the values of chemicals after chlorination, the results of which are shown in [Table 5].
Table 5: Table paired T test chemical parameters before and after chlorination

Click here to view


The nonparametric Spearman correlation test was carried out to determine the possible link between chemical components and chlorine demand of the water and synthetic coefficients due to the lack of normality of the data; the result of this test is given in [Table 6].
Table 6: Correlation between required chlorine to establish residual (0.5 mg/L) and chemical parameters

Click here to view



  Discussion Top


Because of the high correlation coefficients for all resources, the chlorine decomposition follows the second-degree kinetic constant in short-time whereas in long it follows the first-degree kinetic constant term. However, in some research, long term chlorine demand and the formation of halomethanes follow the second-degree kinetic constant. [16]

The maximum value of chlorine decomposition coefficient in long term was related to Well N.3 (-0.092 h -1 ) and its minimum was related to Alimohammadi Well in the Water and Wastewater Office (-0. 0017 h -1 ) and Ohadi Well (-0.019 h -1 ).

According to [Table 5] indicating the effect of chemical components on the chlorine demand of water, due to the lack of normality in data, the Spearman nonparametric correlation test was carried out, which was found that the factors with high chlorine demand were nitrite, ammonia, iron, manganese, and TOC and factors under the effect of chlorination were EC and TDS.

According to Table, effectiveness of factors on the chlorine degeneration was recognized for Short-term degeneration (k 2 ): nitrite, ammonia, iron, EC, and TDS; and Long-term degeneration (k 1 ): nitrite, ammonia, iron, EC, and TDS [Table 6]. The high concentrations in the study was owing to the existing compounds such as ammonia, and nitrate, because the water drainage of manure to the wells and as well as minerals containing iron compounds in the area. In view of the fact that high concentrations of chlorine results in hygienic and economic issues; therefore, these materials should be removed from the wells.

The solution for the problem is deletion of factors affecting chlorine demand. The common method for deletion of ammonia is the use of the natural resins, zeolite, ion exchange, membrane methods, and aeration. In order to remove iron and manganese, the most common methods includes oxidation, sedimentation, and infiltration. For lower inlets, the ion exchange method is also used. Among these methods to remove organic materials aeration or remove with air, oxidation, advanced coagulation, adsorption, biologically active carbon, ion exchange, and membrane methods. [17] This study is unprecedented in its own category across the country. Nothing has been published of the kind in the literature of the field. The present study can act as a milestone for other research and provide a useful manual of addition of chlorine into drinking water of the cities, and thus prevent the high consumption of chlorine in the water.


  Acknowledgments Top


The authors are grateful for the financial and technical support of Golestan Water and Wastewater Company.

 
  References Top

1.Liguori G, Cavallotti I, Arnese A, Amiranda C, Anastasi D, Angelillo IF. Microbiological quality of drinking water from dispensers in Italy. BMC Microbiol 2010;10:19.  Back to cited text no. 1
    
2.Hrudey SE, Hrudey EJ, Safe Drinking Water: Lessons from Recent Outbreaks in Affluent Nations. IWA Publishing, London. 2004.  Back to cited text no. 2
    
3.Lu W, Kiene L, Levi L. Chlorine demand of biofilms in water distribution system. Wat Res 1999; 33 (3): 827-835.  Back to cited text no. 3
    
4.Kiene L, Lu W, Levi Y. Parameters governing the rate of chlorine decay throughout distribution system. AWWA ACE93173, San Antonio 1993: pp. 503-511.  Back to cited text no. 4
    
5.Vasconcelos JJ, Boulos PF, Grayman WM, KieÂne L, Wable O, Biswas P, Bhari A, Rossman LA, Clark RM, Goodrich JA. Characterization and modeling of chlorine decay in distribution systems. AWWA Research Foundation, 1996: ISBN: 0-89867-870-6.  Back to cited text no. 5
    
6.Powell JC, Hallam NB, West JR, Forster CF, Simms J. Factors which control bulk chlorine decay rates. Wat Res 2000;34:117-126.  Back to cited text no. 6
    
7.Vasconcelos JJ, Boulos PF. Characterization and Modeling of Chlorine Decay in Distribution Systems. AWWA-Technology & Engineering, USA 1996.  Back to cited text no. 7
    
8.Vasconcelos JJ, Rossman LA, Grayman WM, Boulos PF, Clark RM. Kinetics of chlorine decay. JAWWA 1997;89:54-65.  Back to cited text no. 8
    
9.Brezonik PL. Chemical Kinetics and Process Dynamics in Aquatic Systems. CRC Press Inc., Boca Raton, 1994.  Back to cited text no. 9
    
10.Warton B, Heitz A, Joll C, Kagi R. A new method for calculation of the chlorine demand of natural and treated waters. Wat Res. 2006;40(15):2877-2884  Back to cited text no. 10
    
11.Wable, O., Dumoutier, N., Duguet, J.P., Jarrige, P.A., Gelas, G., Depierre, J.F., 1991. Modelling chlorine concentrations in a network and applications to Paris distribution network. Water quality modeling in distribution systems. Am Water Works Assoc.Res.Found., 265-76.  Back to cited text no. 11
    
12.Clark RM, Rossman LA, Wymer LJ. Modeling distribution system water quality: Regulatory implications. J Water Resour Plann Manage 1995; 121(6): 423-428.  Back to cited text no. 12
    
13.Rossman LA, Clark RM, Grayman WM. Modelling chlorine residual in drinking-water distribution systems. J Environ Eng 1994;120:803-820.  Back to cited text no. 13
    
14.Vasconcelos JJ, Boulos PF, Clark RM. Kinetic models of chlorine decay in drinking water distribution systems. In: Proceedings of the International Conference on Computer Methods in Water Resources, CMWR., Beirut, Lebanon, 1996: pp. 413-21.  Back to cited text no. 14
    
15.Biswas P, Lu C, Clark RM, A model for chlorine concentration decay in pipes. Wat Res 1993; 27(12): 1715-1724.  Back to cited text no. 15
    
16.Gallard H, von Gunten U. Chlorination of natural organic matter: kinetics of chlorination and of THM formation. Wat Res 2002; 36(1): 65 -74.  Back to cited text no. 16
    
17.Kawamura S. Integrated Design of Water Treatment Facilities. Willy and Sons. 2000.  Back to cited text no. 17
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8], [Figure 9], [Figure 10], [Figure 11], [Figure 12], [Figure 13]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5], [Table 6]



 

Top
Previous article  Next article
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Materials and Me...
Results
Discussion
Acknowledgments
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed2670    
    Printed117    
    Emailed0    
    PDF Downloaded279    
    Comments [Add]    

Recommend this journal