Print this page Email this page
Users Online: 301
Home About us Editorial board Search Browse articles Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 8  |  Issue : 1  |  Page : 2

Linear and nonlinear isotherm modeling of nitrate removal from aqueous solution by alternating current electrocoagulation


1 Department of Environmental Health Engineering; Student Research Committee, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran
2 Department of Environmental Health Engineering, School of Health; Environment Research Center, Research Institute for Primordial Prevention of Noncommunicable Disease, Isfahan University of Medical Sciences, Isfahan, Iran

Correspondence Address:
Bijan Bina
Department of Environmental Health Engineering, School of Health, Isfahan University of Medical Sciences, Isfahan
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijehe.ijehe_9_17

Rights and Permissions

Aims: Nitrates in drinking water which may come from nitrogen fertilizers applied to crops are a potential health risk. The present study was conducted to investigate the application of alternating current (AC) in electrocoagulation (EC) process for nitrate removal from aqueous solution and linear and nonlinear isotherm modeling.Materials and Methods: The experiments were performed in pilot scale. The effective parameters including solution pH, the initial concentration of nitrate, total dissolved solids, contact time, and current density were studied. Results: The obtained results showed that with increasing solution pH from 3 to 10, the sinusoidal removal efficiency was observed. With increasing current density from 0.5 to 2 A/cm2, the nitrate removal efficiency was ascended from 32% to 58%. The optimum electrolyte was 2 g/L of NaCl. With increasing contact time and decreasing initial nitrate concentration, the nitrate removal efficiency was enhanced. In addition, the adsorption NO3by AC EC was preferably fitted with Langmuir isotherm. Conclusion: The results showed that the EC process could remove the nitrate to less than Iranian standard limit. The solution pH, current density, and contact time were showed the direct effect and initial concentration of nitrate depicted the reverse effect on nitrate removal efficiency.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed199    
    Printed19    
    Emailed0    
    PDF Downloaded33    
    Comments [Add]    

Recommend this journal