Print this page Email this page
Users Online: 512
Home About us Editorial board Search Browse articles Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2012  |  Volume : 1  |  Issue : 1  |  Page : 50

Necessity for replacing the filter media in the water treatment plant based on effective size and uniformity coefficient


1 Isfahan Water Treatment Plant, Isfahan Water and Wastewater Company, Isfahan, Iran
2 Environment Research Center, Isfahan University of medical Sciences (IUMS), Isfahan, Iran and Department of Environmental Health Engineering, School of Health, IUMS, Isfahan, Iran
3 Environment Research Center, Isfahan University of medical Sciences (IUMS), Isfahan, Iran and Department of Environmental Health Engineering, School of Health, IUMS, Isfahan; Department of Environmental Health Engineering, School of Public Health, Hormozgan University of Medical Sciences, Bandar Abbas, Iran

Correspondence Address:
Mohsen Heidari
Isfahan University of Medical Sciences, Hezar Jerib Avenue, Isfahan
Iran
Login to access the Email id

Source of Support: Isfahan Water and Wastewater Company, Conflict of Interest: None


DOI: 10.4103/2277-9183.105352

Rights and Permissions

Aims: This study aims to compare the parameters in filtration unit of the plant with international guidelines. The results of this study would determine the necessity for replacing or renewing the anthracite and sand filter beds in phase I of IWTP. Materials and Methods: In this field study, a total of 11 samples with a mass of 5 kg sand and anthracite media were analyzed. The media samples were evaluated in view of uniformity coefficient and effective size according to international soil classification. Data obtained were statistically analyzed using t-test at significance level (P < 0.05). Results: Results of this study showed that the uniformity coefficients of anthracite and sand media were 3.6 ± 0.4 and 1.93 ± 0.11 mm, respectively. Also, the effective sizes of anthracite and sand media were 0.68 ± 0.08 and 0.63 ± 0.05 mm, respectively. These values exceeded the international guidelines and had a significance difference with them (P-value < 0.05). Conclusion: The results were shown that the uniformity coefficient and effective size of sand and anthracite media in the filters used in phase I of IWTP exceeded the guidelines and they need to be replaced with new media. Finally, based on the current study, filter beds were renewed.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4137    
    Printed103    
    Emailed3    
    PDF Downloaded392    
    Comments [Add]    

Recommend this journal